HP3000: Fourth HP 3000 release, update 1
See HP3000/hp3000_release.txt for details of the release
This commit is contained in:
parent
0046905f72
commit
7ac92a0e84
3 changed files with 54 additions and 18 deletions
|
@ -1,6 +1,6 @@
|
|||
/* hp3000_cpu.c: HP 3000 Central Processing Unit simulator
|
||||
|
||||
Copyright (c) 2016, J. David Bryan
|
||||
Copyright (c) 2016-2017, J. David Bryan
|
||||
|
||||
Permission is hereby granted, free of charge, to any person obtaining a copy
|
||||
of this software and associated documentation files (the "Software"), to deal
|
||||
|
@ -25,6 +25,7 @@
|
|||
|
||||
CPU HP 3000 Series III Central Processing Unit
|
||||
|
||||
19-Jan-17 JDB Added comments describing the OPND and EXEC trace options
|
||||
29_Dec-16 JDB Changed the status mnemonic flag from REG_S to REG_T
|
||||
07-Nov-16 JDB Renamed cpu_byte_to_word_ea to cpu_byte_ea
|
||||
03-Nov-16 JDB Added zero offsets to the cpu_call_procedure calls
|
||||
|
@ -509,11 +510,13 @@
|
|||
The trace options that may be specified are:
|
||||
|
||||
Trace Action
|
||||
----- ----------------------------------
|
||||
INSTR trace instruction executions
|
||||
----- -------------------------------------------
|
||||
INSTR trace instructions executed
|
||||
DATA trace memory data accesses
|
||||
FETCH trace memory instruction fetches
|
||||
REG trace registers
|
||||
OPND trace memory operands
|
||||
EXEC trace matching instruction execution states
|
||||
PSERV trace process clock service events
|
||||
|
||||
A section of an example trace is:
|
||||
|
@ -564,12 +567,20 @@
|
|||
instruction that may alter the base registers, the program, data, and stack
|
||||
segment base registers are printed.
|
||||
|
||||
The OPND option traces operand values. Some instructions that take memory
|
||||
and register operands that are difficult to decode from DATA or REG traces
|
||||
present the operand values in a higher-level format. The memory bank and
|
||||
address values are always those of the operands. The operand data and value
|
||||
presented are specific to the instruction; see the instruction executor
|
||||
comments for details.
|
||||
The OPND option traces memory byte operand values. Some instructions take
|
||||
memory and register operands that are difficult to decode from DATA or REG
|
||||
traces. This option presents these operands in a higher-level format. The
|
||||
memory bank and address values are always those of the operands. The operand
|
||||
data and values printed are specific to the instruction. For example, the
|
||||
ALGN instruction prints its source and target operands, digit counts, and
|
||||
fraction counts, and the EDIT instruction displays its subprogram operations.
|
||||
|
||||
The EXEC option traces the execution of instructions that match
|
||||
user-specified criteria. When a match occurs, all CPU trace options are
|
||||
turned on for the duration of the execution of the matched instruction. The
|
||||
prior trace settings are restored when a match fails. This option allows
|
||||
detailed tracing of specified instructions while minimizing the log file size
|
||||
compared to a full instruction trace.
|
||||
|
||||
The PSERV option traces process clock event service entries. Each trace
|
||||
reports whether or not the CPU was executing on the Interrupt Control Stack
|
||||
|
|
|
@ -1,6 +1,6 @@
|
|||
SIMH/HP 3000 RELEASE NOTES
|
||||
==========================
|
||||
Last update: 2017-01-08
|
||||
Last update: 2017-01-23
|
||||
|
||||
|
||||
This file documents the release history of the Hewlett-Packard 3000 simulator.
|
||||
|
@ -11,13 +11,32 @@ simulator code base is available at:
|
|||
https://github.com/simh/simh
|
||||
|
||||
...and may be downloaded at any time. A code snapshot is identified by the "git
|
||||
commit ID" that is displayed by the simulator welcome banner.
|
||||
commit ID" that is displayed in the simulator welcome banner.
|
||||
|
||||
Therefore, HP 3000 releases are simply documentation checkpoints that describe
|
||||
the changes that have occurred since the last checkpoint. Generally, a release
|
||||
is written when one or more major changes have been incorporated. Minor bug
|
||||
fixes will be available immediately but only noted as part of the next release
|
||||
document.
|
||||
fixes will be available immediately from the repository but only noted as part
|
||||
of the next release document.
|
||||
|
||||
|
||||
|
||||
===============================
|
||||
Reporting Bugs in the Simulator
|
||||
===============================
|
||||
|
||||
If you find a bug in the HP 3000 simulator, please report it either to the SIMH
|
||||
issue tracker on github at:
|
||||
|
||||
https://github.com/simh/simh/issues
|
||||
|
||||
...or to the SIMH mailing list; see:
|
||||
|
||||
http://mailman.trailing-edge.com/mailman/listinfo/simh
|
||||
|
||||
...for subscribing information. In either case, please include a console log
|
||||
that contains a reproducible test case that illustrates the problem. See the
|
||||
"Recording Simulator Activities" section of the "SIMH User's Guide" for details.
|
||||
|
||||
|
||||
|
||||
|
@ -58,15 +77,14 @@ PDF version of the same manual is available at:
|
|||
|
||||
A preconfigured MPE-V/R disc image containing the Fundamental Operating Software
|
||||
(FOS), selected SUBSYS language processors (BASIC, BASICOMP, COBOL, COBOLII,
|
||||
FORTRAN, PASCAL, RPG, and SPL), and example programs is available from Bitsavers
|
||||
at:
|
||||
FORTRAN, PASCAL, RPG, and SPL), and example programs is available at:
|
||||
|
||||
http://www.bitsavers.org/bits/HP/HP_3000/
|
||||
http://simh.trailing-edge.com/kits/mpe-vr-software-kit.zip
|
||||
|
||||
The archive contains instructions and simulator command files that allow
|
||||
ready-to-run operation.
|
||||
|
||||
Manuals describing MPE operation are also available from Bitsavers at:
|
||||
Manuals describing MPE operation are available from Bitsavers at:
|
||||
|
||||
http://www.bitsavers.org/pdf/hp/3000/
|
||||
|
||||
|
@ -187,6 +205,13 @@ Implementation Notes
|
|||
routines to the system SL and COBOL example programs to the OPERATOR.SYS
|
||||
account. The startup command files also enable the COBOL II instruction set.
|
||||
|
||||
- If you are using a custom MPE configuration and want to run COBOL II
|
||||
programs, you must perform a SYSDUMP/COLDSTART to replace the three existing
|
||||
COBLIB segments in your SL.PUB.SYS with their COBOL II replacements. The
|
||||
U00U232A.USL.SYS and COB68LIB.PUB.SYS files on the disc image from the
|
||||
software kit contain the replacement segments. See Usage Note 6 in the
|
||||
"readme.txt" file and the "mpe-3-sysdump.log" file in the kit for details.
|
||||
|
||||
- New "hp3000_cpu_cis.c" and "hp3000_mem.c" modules have been added.
|
||||
|
||||
- For this release, checking for interrupts is not performed during execution
|
||||
|
@ -285,7 +310,7 @@ Bugs Fixed
|
|||
the stack, and the instruction is reexecuted. However, the program label
|
||||
has been lost, so control transfers to a random location.
|
||||
|
||||
CAUSE: The instructions obtain the label and then delete the TOS, flush
|
||||
CAUSE: The instructions obtain the labels and then delete the TOS, flush
|
||||
the rest of the stack registers to memory, and then check that SM <= Z,
|
||||
i.e., that the current top of the stack in memory does not exceed the
|
||||
stack limit. If SM > Z, a stack overflow has occurred, and the trap
|
||||
|
|
BIN
doc/simh_doc.doc
BIN
doc/simh_doc.doc
Binary file not shown.
Loading…
Add table